High-performance Silver Contact Riveting Solution: Empowering Electrical Manufacturing With Superior Reliability
Nov 19, 2025
Leave a message
Product Definition
A Silver Contact Riveted Assembly refers to a non-removable functional component in low-voltage electrical products such as relays, contactors, and switches. This component consists of pre-fabricated silver or silver alloy electrical contacts, permanently fixed to a metal support using a specialized riveting process.
Core Manufacturing and Riveting Processes
Cold Riveting: At room temperature, vertical pressure is applied to the Electrical Contact Riveted Brass of the contact using a riveting die, causing plastic deformation and upsetting, thus forming a strong mechanical lock on the back of the support. This process is efficient and low-cost, suitable for most general-purpose electrical products. The key is to precisely control the riveting pressure and deformation to avoid contact cracking or support deformation.
Hot Riveting: For larger contacts or high-hardness silver alloy materials, sometimes a process of locally heating the Brass Stamping Electrical Silver Contact before riveting is used. Heating increases the material's plasticity, reduces the pressure required for riveting, and lowers the risk of internal stress and microcracks, contributing to a denser and stronger riveting joint.
Spin Riveting and Die Riveting:
Die Riveting: Using upper and lower dies to extrude and shape the rivet tail, resulting in fast forming speed and high consistency.
Spin riveting: Using a specialized spin riveting machine, the riveting head rotates while being pressed, achieving shaping through uniform plastic flow. Spin riveting produces a smooth surface and superior internal flow lines, significantly reducing riveting stress and deformation, making it particularly suitable for applications with high reliability requirements.
Finishing and Inspection: After riveting, the Silver Bimetal Contacts with Brass Stamping must be cleaned to remove oil and metal debris. Then, the dimensions and concentricity of the riveted parts are inspected using an optical projector; the riveted area is examined under a microscope for cracks and dents; and the contact strength is measured using tools to ensure it meets standard requirements.

Quality Control and Industry Standards
Dimensional and Geometric Tolerances: Ensure that the position, height, and perpendicularity of the Bimetal Electrical Contacts Rivets with Brass after riveting meet the drawing requirements to guarantee proper contact with the mating contacts.
Joint Strength: This is a core indicator, typically verified through tensile testing or wedge testing. The riveted joint must withstand the specified minimum tensile force without loosening or detachment.
Contact Resistance: Measure the resistance between the Electrical Contact Riveted Brass and the support using a micro-ohmmeter. The resistance must be below the specified upper limit to ensure good conductivity.
Materials and Environmental Protection: The silver contact material must comply with the relevant national standards (GB/T) for electrical contacts, and the support material must comply with the corresponding copper material standards. The entire component must meet the restrictions on hazardous substances stipulated in RoHS and other environmental directives.
our Products
Against this industry backdrop, our company's Silver Contact Riveted Assembly is a high-quality product meticulously crafted based on cutting-edge industry technology and market demands. Our products utilize advanced three-stamping technology and in-mold riveting to ensure a tight bond between the silver contacts and the copper components. This not only improves the product's mechanical strength and electrical performance but also significantly reduces the amount of silver used, effectively controlling production costs.
Our Bimetal Electrical Contacts Rivets with Brass undergo rigorous control at every stage of production, from the selection of raw materials to the inspection of finished products, adhering to the highest quality standards. The products undergo strict aging and electrical performance testing to ensure stable performance under various complex operating conditions.

contact us

Send Inquiry